Pressure drop information for extractor vents
NB It is important not to reduce the exhaust pipe diameter through the roof terminal, i.e. don't take a 125mm pipe out through the 100mm diameter roof terminal.
Tileline Tilevent
Airflow resistance when used as SVP/extract terminals Calculated using SUA (Soil Universal Adaptor).
54m3 /hr (15 litres/sec) 17 Pa
108m3 /hr (30 litres/sec) 67 Pa
216m3 /hr (60 litres/sec) 265 Pa
TileLine Half Round Ridge Vent
Airflow resistance when used as SVP/extract terminals
100mm Pipe diameter
54m3 /h (15 litres/sec) 2.5Pa
108m3 /h (30 litres/sec) 8.1Pa
216m3 /h (60 litres/sec) 29.6Pa
125mm Pipe diameter
54m3 /h (15 litres/sec) 2.3Pa
108m3 /h (30 litres/sec) 9.3Pa
216m3 /h (60 litres/sec) 36.9Pa
TileLine 90o Angle Ridge Vent
Airflow resistance when used as SVP/extract terminals
100mm Pipe diameter
54m3 /h (15 litres/sec) 6.7Pa
108m3 /h (30 litres/sec) 26.2Pa
216m3 /h (60 litres/sec) 103.8Pa
125mm Pipe diameter
54m3 /h (15 litres/sec) 5.8Pa
108m3 /h (30 litres/sec)26.5Pa
216m3 /h (60 litres/sec) 110.3Pa
TileLine 105o Angle Ridge
Airflow resistance when used as SVP/extract terminals
100mm Pipe diameter
54m3 /h (15 litres/sec) 3.7Pa
108m3 /h (30 litres/sec) 14.5Pa
216m3 /h (60 litres/sec) 57.2Pa
125mm Pipe diameter
54m3 /h (15 litres/sec) 4.4Pa
108m3 /h (30 litres/sec)16.4Pa
216m3 /h (60 litres/sec) 63.2Pa
TileLine 115o Angle Ridge
Airflow resistance when used as SVP/extract terminals
100mm Pipe diameter
54m3 /h (15 litres/sec) 3.2Pa
108m3 /h (30 litres/sec) 11.7Pa
216m3 /h (60 litres/sec) 44.9Pa
125mm Pipe diameter
54m3 /h (15 litres/sec) 3.9Pa
108m3 /h (30 litres/sec)13.9Pa
216m3 /h (60 litres/sec) 52.9Pa